Specifications:
Input Voltage: 88~132VAC / 176~264VAC (selectable by switch)
Inrush Current: Cold start, 18A at 115VAC, 36A at 230VAC
Ambient Operating Temperature: 0-40°C@100%, -10°C@80%, 60°C@60% load
Protection: Short circuit, Overload (105%~135% hiccup mode, auto-recovery), Over voltage (115%~145% rated output voltage)
Approvals: UL, CUL
Packing: 1.08kg; 12pcs / 13.8kg / 0.92CUFT
Testing: 100% full load burn-in test
Cooling: Forced air cooling by built in DC Fan Cooling fan On/Off auto control
Safety Standards: UL1012, UL60950-1, TUV EN60950-1 approved
EMC Standards: UL60950-1 approved
Withstand Voltage: I/P-O/P:3kVAC, I/P-FG:1.5kVAC, 1 minute
Connection: 9P/9.5mm pitch terminal block
Output: 24V, 0~12.5A (±10% DC adjustment range)
R&N: 150mV
Efficiency: 86%
Tolerance: ±1%
Setup, rise, hold-up time:2000ms, 20ms, 24ms at full load and 230VAC
Switching Frequency: 90kHz (fixed)